Structured Cabling in Matale

Tidy, tested cabling every system can rely on.

Cat6 and fibre runs, patch panels and racks — labelled, tested and documented at handover.

  • Free site visitWithin our service areaනොමිලේ පැමිණ බලනවා
  • Written quote before work startsවැඩට පෙර ලිඛිත මිල ගණන්
  • Warranty on installationsTerms vary by equipmentසෑම වැඩකටම වොරන්ටි
Google rating
4.9Google rating
years in Kandy
10+years in Kandy
systems installed, all services
500+systems installed, all services
towns served
29towns served

Prefer a call?

Leave your details and we'll discuss your cabling requirements.

Enquiry forStructured Cabling

Used only to reply to this enquiry. Privacy policy

Before a new office opens in Matale or a school fills a computer lab with machines, the cabling behind the walls has to be right, because so many later network problems trace back to it. We take a job through each stage: planning the routes, pulling cable, terminating it at both ends, then testing and certifying every run. Plenty of offices in the town, including those around the district hospital and the government buildings, occupy older structures where solid walls and earlier alterations leave little room, so we work out how cable will travel around them during the survey instead of discovering obstacles halfway through. For most offices Cat6 is the sensible choice; Cat6a is kept for server rooms and for backbone links running between floors. When the work is finished you receive labelled outlets, a labelled patch panel and as-built drawings, so anyone maintaining the network in future can trace each connection.

What we plan for in Matale

  • Multi-storey shophouses on the main street rarely have spare ducts, so a single riser route is agreed with the owner early, keeping cables off the frontage and away from signboard fixings.
  • School computer labs are rearranged often, so data points run along the walls with spare outlets, allowing desk layouts to change without calling anyone back to add cabling.
  • Roof spaces under metal sheeting get very hot in Matale, which reduces cable performance over long runs, so routes are kept out of those voids wherever a lower path exists.

Scope

What structured cabling includes

  • Cat5e, Cat6, and Cat6a cabling
  • Fibre optic installation
  • Patch panel and rack setup
  • Cable management and labelling
  • Testing and certification
  • Floor and ceiling trunking
  • Server room setup
  • As-built documentation

How it works

From enquiry to handover, in three steps

01

Site survey

We walk the building, plan cable routes, and count the data points needed per room.

02

Written quote

An itemised quote covering cable, containment, patch panels, and testing/certification.

03

Install & certify

We terminate, label, and test every run, and hand over as-built documentation.

Pricing

What changes the price

Every job is different, so we quote in writing after a free survey — not off a fixed price list. These are the main factors:

  1. 1Number of data points needed
  2. 2Cat6 vs. Cat6a vs. fibre backbone
  3. 3Floor and ceiling trunking / cable management
  4. 4Testing and certification requirements

FAQ

Structured Cabling in Matale — questions

Yes, and it is the best time to do it. We plan the work around the school's term dates, and larger jobs can be split into stages so each room is finished, tested and usable before the next one starts. Where some work must happen during term, noisy tasks such as drilling are arranged for after classes, with the lab left safe and tidy each day.

Sometimes. Each run is tested first, and cable that passes certification at the category you need can stay in service. Older Cat5 or damaged cable, or runs that no longer reach where the new desks will be, are better replaced. We give you the test results so the decision is based on measurements rather than guesswork.

Cat5e is the budget option and fine for basic needs; Cat6 is the sensible default for most modern offices; and Cat6a supports 10-gigabit speeds, worth it for server rooms and backbone runs but rarely necessary for individual desks. For most offices we run Cat6 to workstations and Cat6a only on the backbone.

We recommend two data points per desk — one for a computer and one spare for a phone, printer, or future need — rather than exactly one per person. Retrofitting a single missed point after the finishes are complete costs far more than including it upfront.

Cabling during construction, before walls close up, is significantly cheaper per point than retrofitting into a finished space, where cables must be routed around existing finishes. If you're planning a new fit-out, involve your cabling provider at the same stage as your electrician.

Yes. Every structured cabling installation includes termination, testing, and certification documentation. Untested cabling can look fine on day one and cause intermittent faults months later that are far more expensive to diagnose — so certification is standard, not an optional extra.

For a typical 20-person office in the Kandy area, professional structured cabling runs between LKR 150,000 and LKR 300,000 depending on cable type and layout complexity, including data points at each workstation, patch panels, a network cabinet, and testing certification. We provide a detailed quotation after a free site survey.

10+

Years in Kandy

500+

Systems installed

4.9★

110+ reviews

1yr+

Warranty

Trusted Brands We Work With

Hikvision logo
Dahua logo
EZVIZ logo
Xiaomi logo
TP-Link logo
Cisco logo
D-Link logo
Kelani Cables logo
Seagate logo
Western Digital logo
Hikvision logo
Dahua logo
EZVIZ logo
Xiaomi logo
TP-Link logo
Cisco logo
D-Link logo
Kelani Cables logo
Seagate logo
Western Digital logo

Book a free structured cabling survey in Matale

Professional structured cabling for homes and businesses in Matale, Sri Lanka — free site survey, written quote, no obligation.