Structured cabling • Menikhinna
Structured Cabling in Menikhinna
Tidy, tested cabling every system can rely on.
Cat6 and fibre runs, patch panels and racks — labelled, tested and documented at handover.
- Free site visitWithin our service areaනොමිලේ පැමිණ බලනවා
- Written quote before work startsවැඩට පෙර ලිඛිත මිල ගණන්
- Warranty on installationsTerms vary by equipmentසෑම වැඩකටම වොරන්ටි
- Google rating
- 4.9Google rating
- years in Kandy
- 10+years in Kandy
- systems installed, all services
- 500+systems installed, all services
- towns served
- 29towns served
Prefer a call?
Leave your details and we'll discuss your cabling requirements.
Before new computers, phones or cameras arrive at a Menikhinna office or school lab, the cabling behind them needs to be right, and that is the work we handle from start to finish: planning routes, pulling and terminating cable, then testing and certifying every run. Much of the town centre is made up of older buildings where walls cannot simply be opened, so routes are worked out around beams, columns and existing fittings during a free initial survey rather than improvised on the day. For most offices in Menikhinna, Cat6 offers plenty of capacity; Cat6a is used only where it pays off, on server-room and cabinet-to-cabinet links, where the extra headroom is worthwhile. Every outlet and panel port carries a label, and the handover pack includes drawings of each cable route, which makes moves, additions and fault-finding far simpler years later.
What we plan for in Menikhinna
- Town-centre buildings along the A26 may have concrete slab ceilings with no void above, leaving surface trunking or floor-level conduit as the practical routes; paintable trunking keeps offices presentable.
- School computer rooms need a point at every desk plus spare capacity, with cables routed where students cannot pull or trip on them and a locked rack protecting the switch.
- Where offices share a building, the incoming line and power supply may belong to the landlord, so agreeing where a rack can be placed and powered avoids disputes later on.
Scope
What structured cabling includes
- Cat5e, Cat6, and Cat6a cabling
- Fibre optic installation
- Patch panel and rack setup
- Cable management and labelling
- Testing and certification
- Floor and ceiling trunking
- Server room setup
- As-built documentation
How it works
From enquiry to handover, in three steps
Site survey
We walk the building, plan cable routes, and count the data points needed per room.
Written quote
An itemised quote covering cable, containment, patch panels, and testing/certification.
Install & certify
We terminate, label, and test every run, and hand over as-built documentation.
Pricing
What changes the price
Every job is different, so we quote in writing after a free survey — not off a fixed price list. These are the main factors:
- 1Number of data points needed
- 2Cat6 vs. Cat6a vs. fibre backbone
- 3Floor and ceiling trunking / cable management
- 4Testing and certification requirements
FAQ
Structured Cabling in Menikhinna — questions
Usually, yes. Surface-mounted trunking fixed with minimal drilling carries cables neatly along walls and can be removed if you move out, with the landlord's agreement. A compact wall cabinet holds the switch and patch panel. Routes are agreed with you and the owner beforehand and everything is documented, so the installation can be extended or handed back cleanly when the lease ends.
Each workstation needs its own tested point, plus points for the teacher's desk, a projector or smart board, and a printer. Cables are best run in trunking along the walls or through floor boxes rather than across walkways. A small locked rack in the lab or a nearby office holds the switch, and every point is labelled so a fault at one desk can be traced without guesswork.
Cat5e is the budget option and fine for basic needs; Cat6 is the sensible default for most modern offices; and Cat6a supports 10-gigabit speeds, worth it for server rooms and backbone runs but rarely necessary for individual desks. For most offices we run Cat6 to workstations and Cat6a only on the backbone.
We recommend two data points per desk — one for a computer and one spare for a phone, printer, or future need — rather than exactly one per person. Retrofitting a single missed point after the finishes are complete costs far more than including it upfront.
Cabling during construction, before walls close up, is significantly cheaper per point than retrofitting into a finished space, where cables must be routed around existing finishes. If you're planning a new fit-out, involve your cabling provider at the same stage as your electrician.
Yes. Every structured cabling installation includes termination, testing, and certification documentation. Untested cabling can look fine on day one and cause intermittent faults months later that are far more expensive to diagnose — so certification is standard, not an optional extra.
For a typical 20-person office in the Kandy area, professional structured cabling runs between LKR 150,000 and LKR 300,000 depending on cable type and layout complexity, including data points at each workstation, patch panels, a network cabinet, and testing certification. We provide a detailed quotation after a free site survey.